Basit öğe kaydını göster

dc.contributor.authorYeşiltepe, Ömer
dc.contributor.authorKahraman, Mehmet Şerif
dc.contributor.authorTüredi, Yakup
dc.contributor.authorÖrnek, Murat
dc.date.accessioned2022-12-23T05:56:09Z
dc.date.available2022-12-23T05:56:09Z
dc.date.issued2022en_US
dc.identifier.citationYeşiltepe, Ö., Kahraman, M. Ş., Türedi, Y. & Örnek, M. (2022). Mikrogrid Donatı ile Güçlendirilmiş Zeminde Dairesel Temel Taşıma Gücünün Deneysel Olarak İncelenmesi. Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi, 22 (4) , 850-857. https://doi.org/10.35414/akufemubid.1108530en_US
dc.identifier.urihttps://doi.org/10.35414/akufemubid.1108530
dc.identifier.urihttps://dergipark.org.tr/tr/pub/akufemubid/issue/72533/1108530
dc.identifier.urihttps://hdl.handle.net/20.500.12508/2452
dc.description.abstractZayıf zeminlerde inşa edilen yapıların temel tasarımı oldukça önemlidir. Bu tür zeminlerde yüzeysel temeller yetersiz kalıyorsa ya bir zemin iyileştirme yöntemi uygulanmalı ya da uygun görülen bir derin temel sistemi tercih edilmelidir. Zayıf zeminlere geosentetik donatılar yerleştirilerek zeminin taşıma gücü bakımından iyileştirilmesi mümkün olmaktadır. Bu çalışmada daire ve kare kesitlerde hazırlanmış mikrogrid donatı yerleştirilerek güçlendirilmiş gevşek kum zemine yerleştirilen daire temelin eksenel kuvvet altındaki davranışını gözlemlemek için 31 adet laboratuvar deneyi yapılmıştır. Donatının derinliği, donatıların genişliği/çapı, donatıların geometrileri değiştirilerek taşıma gücü bakımından optimum donatı parametreleri yapılan deneylerle araştırılmıştır. Deneyler sonucunda mikrogrid donatıların daire temelin taşıma gücünü arttırdığı tespit edilmiştir. Ayrıca mikrogrid donatıların optimum parametreleri belirlenmiştir.en_US
dc.description.abstractThe footing design of buildings to be built in areas where loose soil condition, is very important. If the shallow foundations are insufficient in such soils, either a soil improvement method should be applied or a suitable deep foundation system should be preferred. It is possible to improve the bearing capacity of the soil by placing geosynthetic reinforcements on loose soils. In this study, 31 laboratory tests have been conducted to observe the behavior of the circular foundation on loose sand soil reinforced with circular and square microgrid reinforced under axial force. The optimum reinforcement parameters were investigated with laboratory tests by changing the reinforcement depth, the width / diameter of the reinforcement, the reinforcement geometry. As a result of the tests, it was determined that the microgrid reinforcements increase the circular footing bearing capacity. In addition, optimum parameters of microgrid reinforcements were determined.en_US
dc.language.isoturen_US
dc.publisherAfyon Kocatepe Üniversitesien_US
dc.relation.isversionof10.35414/akufemubid.1108530en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMikrogrid donatıen_US
dc.subjectDaire temelen_US
dc.subjectZemin iyileştirmeen_US
dc.subjectTaşıma gücüen_US
dc.subjectLaboratuvar deneyien_US
dc.subject.classificationİnşaat Mühendisliği
dc.titleMikrogrid Donatı ile Güçlendirilmiş Zeminde Dairesel Temel Taşıma Gücünün Deneysel Olarak İncelenmesien_US
dc.title.alternativeExperimental Investigation of the Circular Footing Bearing Capacity Rested on Microgrid Reinforced Soilen_US
dc.typearticleen_US
dc.relation.journalAfyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisien_US
dc.contributor.departmentMühendislik ve Doğa Bilimleri Fakültesi -- İnşaat Mühendisliği Bölümüen_US
dc.identifier.volume22en_US
dc.identifier.issue4en_US
dc.identifier.startpage850en_US
dc.identifier.endpage857en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.isteauthorKahraman, Mehmet Şerif
dc.contributor.isteauthorTüredi, Yakup
dc.contributor.isteauthorÖrnek, Murat
dc.relation.indexTR-Dizinen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster