Basit öğe kaydını göster

dc.contributor.authorÖztürk, Murat
dc.contributor.authorAkgöl, Oğuzhan
dc.contributor.authorSevim, Umur Korkut
dc.contributor.authorKaraaslan, Muharrem
dc.contributor.authorDemirci, Mustafa
dc.contributor.authorÜnal, Emin
dc.date.accessioned12.07.201910:50:10
dc.date.accessioned2019-07-12T22:06:14Z
dc.date.available12.07.201910:50:10
dc.date.available2019-07-12T22:06:14Z
dc.date.issued2018
dc.identifier.citationOzturk, M., Akgol, O., Sevim, U.K., Karaaslan, M., Demirci, M., Unal, E. (2018). Experimental work on mechanical, electromagnetic and microwave shielding effectiveness properties of mortar containing electric arc furnace slag. Construction and Building Materials, 165, pp. 58-63. https://doi.org/10.1016/j.conbuildmat.2018.01.031en_US
dc.identifier.issn0950-0618
dc.identifier.issn1879-0526
dc.identifier.urihttps://doi.org/10.1016/j.conbuildmat.2018.01.031
dc.identifier.urihttps://hdl.handle.net/20.500.12508/672
dc.descriptionWOS: 000428229100006en_US
dc.description.abstractIt is well known that one of the widely used structural materials is ordinary cement mortar. Whereas the mechanical properties are sufficient as structural materials, its shielding effectiveness and prevention properties of microwave signal is insufficient due to the lack of electromagnetically conductive components. Electric Arc Furnace Slag (EAFS) is a by-product which is produced after the melting and the primary acid refining of liquid steel. It has potential to improve both mechanical and electrical properties of cement. In this study, ordinary cement mortar specimens with Electric Arc Furnace Slag are investigated. The EAFS used in this study takes part in the mortar specimens as aggregate. Electrical properties are measured by a vector network analyzer in the frequency range of 3-18 GHz. Both the reflection and transmission of the proposed specimens exposed to EM wave are evaluated by free space measurement techniques at the same frequency range. The compressive strength, flexural tensile strength and shielding effectiveness of mortars are also tested, respectively. The real part of permittivity increases with the increased EAFS content of the mortars up to dielectric constant of 40. Nearly constant and frequency independent characteristics of specimens have potential applications. Furthermore, the effective dielectric constant of permeability of the mortars is explicitly improved in the related frequency ranges with the addition of the EAF slags. The transmission prevention of the EAF slag mortars tend to increase significantly with the increasing ratio of EAF slag content. The minimum transmission is around -70 dB and the transmission below -10 dB for 40% EAF aggregate ratio in mortar which has the best mechanical properties in the entire frequency range and averagely and it is -10 dB lower than that of the cement without EAF aggregates. The shielding effectiveness is in excellent level for 80% and 100% EAFS aggregate levels and that of 40% aggregate ratio is still in a good level with a value varying between 15 dB and 20 dB. Besides, the mortars with 40% EAF slag content exhibit approximately 7 MPa higher compressive strength value and 0.9 MPa higher flexural tensile strength. (C) 2018 Elsevier Ltd. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.conbuildmat.2018.01.031en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEAFSen_US
dc.subjectMechanicen_US
dc.subjectElectromagneticen_US
dc.subjectShielding effectivenessen_US
dc.subjectMortaren_US
dc.subject.classificationConstruction & Building Technologyen_US
dc.subject.classificationEngineeringen_US
dc.subject.classificationCivilen_US
dc.subject.classificationMaterials Scienceen_US
dc.subject.classificationMultidisciplinaryen_US
dc.subject.classificationBasic Oxygen Converter | Slag | Arc Furnaceen_US
dc.subject.otherInterferenceen_US
dc.subject.otherAggregatesen_US
dc.subject.otherCementsen_US
dc.subject.otherCompressive strengthen_US
dc.subject.otherConductive materialsen_US
dc.subject.otherElectric arcsen_US
dc.subject.otherElectric furnace processen_US
dc.subject.otherElectric network analyzersen_US
dc.subject.otherElectromagnetic shieldingen_US
dc.subject.otherElectromagnetic wavesen_US
dc.subject.otherFurnacesen_US
dc.subject.otherMagnetic shieldingen_US
dc.subject.otherMechanical propertiesen_US
dc.subject.otherMechanicsen_US
dc.subject.otherSlagsen_US
dc.subject.otherTensile strengthen_US
dc.subject.otherTransmissionsen_US
dc.subject.otherEffective dielectric constantsen_US
dc.subject.otherElectric arc furnace slagsen_US
dc.subject.otherMechanical and electrical propertiesen_US
dc.subject.otherReflection and transmissionen_US
dc.subject.otherVector network analyzersen_US
dc.subject.otherElectric furnacesen_US
dc.titleExperimental work on mechanical, electromagnetic and microwave shielding effectiveness properties of mortar containing electric arc furnace slagen_US
dc.typearticleen_US
dc.relation.journalConstruction and Building Materialsen_US
dc.contributor.departmentMühendislik ve Doğa Bilimleri Fakültesi -- İnşaat Mühendisliği Bölümüen_US
dc.contributor.departmentMühendislik ve Doğa Bilimleri Fakültesi -- Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.identifier.volume165en_US
dc.identifier.startpage58en_US
dc.identifier.endpage63en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.isteauthorÖztürk, Muraten_US
dc.contributor.isteauthorAkgöl, Oğuzhanen_US
dc.contributor.isteauthorSevim, Umur Korkuten_US
dc.contributor.isteauthorKaraaslan, Muharremen_US
dc.contributor.isteauthorDemirci, Mustafaen_US
dc.contributor.isteauthorÜnal, Eminen_US
dc.relation.indexWeb of Science - Scopusen_US
dc.relation.indexWeb of Science Core Collection - Science Citation Index Expandeden_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster