dc.contributor.author | Akyıldırım, Onur | |
dc.contributor.author | Yüksek, Haydar | |
dc.contributor.author | Gürsoy Kol, Özlem | |
dc.contributor.author | Manap, Sevda | |
dc.contributor.author | Beytur, Murat | |
dc.contributor.author | Yola, Mehmet Lütfi | |
dc.date.accessioned | 12.07.201910:50:10 | |
dc.date.accessioned | 2019-07-12T22:06:20Z | |
dc.date.available | 12.07.201910:50:10 | |
dc.date.available | 2019-07-12T22:06:20Z | |
dc.date.issued | 2018 | |
dc.identifier.citation | Akyıldırım, O., Yüksek, H., Kol, Ö.G., Manap, S., Beytur, M., Yola, M.L. (2018). A novel Cu(II) detection assay via modified glassy carbon electrode. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 24(7), 1284-1286.
https://doi.org/10.5505/pajes.2017.46762 | en_US |
dc.identifier.issn | 1300-7009 | |
dc.identifier.issn | 2147-5881 | |
dc.identifier.uri | https://doi.org/10.5505/pajes.2017.46762 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12508/696 | |
dc.description | WOS: 000453906100007 | en_US |
dc.description.abstract | Copper (Cu(II)) is an essential and necessary micronutrient for many plants and animals at very low levels. However, it is toxic to aquatic plants at high levels due to its association with cell membranes. Glassy carbon electrode (GCE) was modified by the 3-phenyl-4-[2-(2-naphthylsulfonyloxy)-benzylidenamino]-4,5-dihydro-1H-1,2,4-triazol-5-one (3-PNO) in 0.1 M supporting electrolyte. The modified surface was confirmed by cyclic voltammetry (CV) and x-ray photoelectron spectroscopy (XPS). According to characterization data, the GCE with 3PNO was successfully obtained. The GCE with 3-PNO was utilized for Cu(II) ions analysis in water samples. The concentration range and the limit of detection (LOD) were 1.0x10-10 -2.0x10-8 M and 2.0x10-11 M (S/N = 3), respectively. | en_US |
dc.description.sponsorship | [2014-MMF-43] | en_US |
dc.description.sponsorship | The authors thank to Kafkas University Scientific Research Projects Coordination (2014-MMF-43). | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Pamukkale University | en_US |
dc.relation.isversionof | 10.5505/pajes.2017.46762 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | 3-PNO | en_US |
dc.subject | Modification | en_US |
dc.subject | Cu(II) ion analysis | en_US |
dc.subject | Modifikasyon | en_US |
dc.subject | Cu(II) iyon analizi | en_US |
dc.subject.classification | Engineering | en_US |
dc.subject.classification | Multidisciplinary | en_US |
dc.subject.other | Gold nanoparticles | en_US |
dc.subject.other | Copper | en_US |
dc.subject.other | Cadmium(II) | en_US |
dc.subject.other | Quercetin | en_US |
dc.subject.other | Biosensor | en_US |
dc.subject.other | Removal | en_US |
dc.subject.other | Lead | en_US |
dc.title | A novel Cu(II) detection assay via modified glassy carbon electrode | en_US |
dc.title.alternative | Modifiye edilmiş camsı karbon ile yeni bir Cu(II) analiz yöntemi | en_US |
dc.type | article | en_US |
dc.relation.journal | Pamukkale University Journal Of Engineering Sciences | en_US |
dc.relation.journal | Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi | en_US |
dc.contributor.department | Mühendislik ve Doğa Bilimleri Fakültesi -- Biyomedikal Mühendisliği Bölümü | en_US |
dc.contributor.authorID | 0000-0003-1090-695X | en_US |
dc.contributor.authorID | 0000-0003-1289-1800 | en_US |
dc.contributor.authorID | 0000-0003-2637-9023 | en_US |
dc.contributor.authorID | 0000-0002-5025-9622 | en_US |
dc.contributor.authorID | 0000-0002-7098-5592 | en_US |
dc.contributor.authorID | 0000-0001-7424-3425 | en_US |
dc.identifier.volume | 24 | en_US |
dc.identifier.issue | 7 | en_US |
dc.identifier.startpage | 1284 | en_US |
dc.identifier.endpage | 1286 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.isteauthor | Yola, Mehmet Lütfi | en_US |
dc.relation.index | Web of Science Core Collection - Emerging Sources Citation Index | en_US |
dc.relation.index | Web of Science - TR-Dizin | en_US |