A novel Cu(II) detection assay via modified glassy carbon electrode

Göster/ Aç
Tarih
2018Yazar
Akyıldırım, OnurYüksek, Haydar
Gürsoy Kol, Özlem
Manap, Sevda
Beytur, Murat
Yola, Mehmet Lütfi
Üst veri
Tüm öğe kaydını gösterKünye
Akyıldırım, O., Yüksek, H., Kol, Ö.G., Manap, S., Beytur, M., Yola, M.L. (2018). A novel Cu(II) detection assay via modified glassy carbon electrode. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 24(7), 1284-1286. https://doi.org/10.5505/pajes.2017.46762Özet
Copper (Cu(II)) is an essential and necessary micronutrient for many plants and animals at very low levels. However, it is toxic to aquatic plants at high levels due to its association with cell membranes. Glassy carbon electrode (GCE) was modified by the 3-phenyl-4-[2-(2-naphthylsulfonyloxy)-benzylidenamino]-4,5-dihydro-1H-1,2,4-triazol-5-one (3-PNO) in 0.1 M supporting electrolyte. The modified surface was confirmed by cyclic voltammetry (CV) and x-ray photoelectron spectroscopy (XPS). According to characterization data, the GCE with 3PNO was successfully obtained. The GCE with 3-PNO was utilized for Cu(II) ions analysis in water samples. The concentration range and the limit of detection (LOD) were 1.0x10-10 -2.0x10-8 M and 2.0x10-11 M (S/N = 3), respectively.
Kaynak
Pamukkale University Journal Of Engineering SciencesPamukkale Üniversitesi Mühendislik Bilimleri Dergisi